Sampling Pump BiVOC2, 2 Channels

Item number: H01-315

  • ideally suitable for sampling of VOCs and aldehydes with just one pump!
  • BiVOC2 - the 2-channel sampling pump for air sampling
  • 2-channel sampling pump BiVOC2
  • precise control unit for each channel
  • each channel can be individually set up
  • 10 editable preset programs
  • US-standard, German-standard and volumetric litres
  • Configurable interval mode (since version 2.1)
  • more cost effective than 2 single pumps (with comparable technical specifications)
  • Category: Air Sampling


    4.316,13 €

    including19% VAT.

    Exp. shipping time: ca. 2 weeks

    : 0 workdays

    pc.


    Description

    Sampling Pump BiVOC2, 2 Channels

    • ideally suitable for sampling of VOCs and aldehydes with just one pump!
    • BiVOC2 - the 2-channel sampling pump for air sampling
    • 2-channel sampling pump BiVOC2
    • precise control unit for each channel
    • each channel can be individually set up
    • 10 editable preset programs
    • US-standard, German-standard and volumetric litres
    • Configurable interval mode (since version 2.1)
    • more cost effective than 2 single pumps (with comparable technical specifications)

    The compact 2-channel pump BiVOC2 allows you to perform simultaneous dual air-sampling in the range of low volume flow starting at 0.1 litres/min.
    Perfect for air-sampling on TENAX sample-media with 0.1 SL/min volume flow.
    Of course, other sample-media can be loaded as well- such as activated carbon tubes, DNPH cartridges and silica gel- with a volume flow of max. 1.9 litres/min*.
    *The maximum achievable flow rate is determined by the differential pressure dependent on the sample-medium.

    You can freely store up to 10 preset programs.
    Start delay and interval mode can also be configured, naturally.
    BiVOC2 supports the volume types standard litres, normal litres and volumetric litres (with optional climate sensor HC2-S).
    The data of the last 64 samplings can be viewed on the display.
    The high target volume range of up to 5000 litres allows to use the BiVOC2 to generate a precise exchange rate for air in test chambers- along with ?automatic? documentation when data logging is enabled.
    The power of the pump is automatically regulated according to the current requirements. That way, a battery runtime of up to 15 hours can be reached.

    Sampling is getting more easy and relibale with BiVOC2:
    • Connect sample medium
    • Select preset program
    • Press start
    The rest is done by BiVOC2- you can address yourself unstressed to other tasks.


    Technical data:
    Number of sampling channels: 2 individually controlled channels
    Volume flow: 0.1 to 1.1 SL/min per channel, dependent on the necessary negative pressure pre-selectable up to 1.9 SL/min (e.g. channel 1 with 0.1 SL/min and channel 2 with 1.9 SL/min)
    Sampling air volume: 0.5 to 5,000 SL (US-standard litres 0 C / 1013 hPa), Ls (German-standard litres 20 C / 1013 hPa) and L (litres cur. temperature and air pressure, with optional temperature sensor)
    Data storage: 64 sampling data (ring buffer), 3840 records for sampling log, (storage intervals for sampling log selectable in the range of 1s to 240s)
    Start delay: selectable for each channel from 5 seconds up to 24 hours
    Interval mode: configurable to extend the sampling duration for combined samplings with the same time window (to avoid possible overload, since firmware version 2.1)
    Presettings: up to 10 presettings (volumes, volume flows, start delay per channel)
    Operator guidance: German / English
    Operation: keypad with 5 keys
    Display: large illuminated LC display, 4 lines each with 20 characters
    Status signaling: status display with multi-colored LED per channel, acoustic signal generator
    Flow measurement: flow sensor for each channel with upstream 10 m protection filter cartridge
    Accuracy: volume flow: 2.0 % of the measured value plus 0.002 SL/min
    volumes: 2.5 % of the measured value
    Air conveying mechanism: maintenance-free membrane pump with controlled brushless drive
    Energy supply: internal Lithium-Polymer battery pack (up to 15 hours of operation at 2 x 0.1 litres/min)
    Charger: 100 - 240 Volt AC, charging current max. 2A, included in delivery
    Sample air inlet: via lockable 3/16? plug-in couplings made of chrome plated brass
    Sample air outlet: via a lockable 3/16? plug-in coupling made of plastic
    PC connection: USB socket (type B) on the rear side
    PC software: for Microsoft Windows XP, 7 / 8, included in delivery
    Dimensions (W x H x D): 180mm x 125mm x 255mm
    Weight: 2480g
    Tripod sockets: UNC 1/4 inch (photo) and UNC 3/8 inch (microphone)


    Scope of delivery:
    • Basic unit BiVOC2V2
    • 1m silicone hose
    • Silencer
    • Y-piece
    • Quick Charger
    • Operation manual
    • USB connection cable
    • Software BivOCControl for configuration, remote control and data exchange
    • Spare fuse


    Optional accessories:
    External. temperature and humidity sensor Rotronic Hygroclip2 (HC2-S), pluggable into socket on the device?s rear side
    Sample-media bracket for fixing of the sample-media, approx. 25 cm, with quick release plate
    Carbon tripod with 1/4" UNC thread (common photo tripod thread)
    Handling case with PE foam cut-outs, available in light gray, anthracite and sapphire blue

    Ratings (0)

    Average product review

    Write your first review and help others with their purchase decision: