Best sellers

-
: 6 - 8 Workdays (DE - int. shipments may differ)
207,06 € *
Best sellers

-
: 11 - 13 Workdays (DE - int. shipments may differ)
212,13 € *
Best sellers

-
: 8 - 10 Workdays (DE - int. shipments may differ)
189,57 € *
Price range
€
€
Special items
Filter
- SKU:
- ND10ff
- SKU:
- M1-7UR4A.000X.372AD
- SKU:
- MB1-33RVOff
- Item weight:
- 0,09 kg
- 30 segments bargraph display
- vertical front panel mounting, 24 x 96mm
- segment colour: red/green selectable, optionally blue/red, orange/green
- small mounting depth: 60mm without the pluggable screw terminal
- parametrization via HEX switch and push button
- factory preadjusted input for standard signal 0 to 10V and 0/4 to 20mA
- free adjustment at the input signal possible
- 8 different types of presentation, parametrizable as bar, dot/point or curtain
- free direction selection and central display (for example, beams out of the centre)
- stepwise brightness control
- protection rate IP65 on the front
- plug-in screw terminal
- SKU:
- MB-3ff
- Variations in:
-
- Mounting/auxiliary voltage
- SKU:
- MB1-33RHOff
- Variations in:
-
- Supply Voltage
- Item weight:
- 0,09 kg
- 30 segments bargraph display
- horizontal front panel mounting, 24 x 96mm
- segment colour: red/green selectable, optionally blue/red, orange/green
- small mounting depth: 60mm without the pluggable screw terminal
- parametrization via HEX switch and push button
- factory preadjusted input for standard signal 0 to 10V and 0/4 to 20mA
- free adjustment at the input signal possible
- 8 different types of presentation, parametrizable as bar, dot/point or curtain
- free direction selection and central display (for example, beams out of the centre)
- stepwise brightness control
- protection rate IP65 on the front
- plug-in screw terminal
- SKU:
- N21-00M0
- Panel mounting
- Universal input (measurement of temperature and standard signals)
- New range for DC voltage measurements: ±75mV
- Relay alarm output
- Universal power supply from 24 to 230VAC/DC
- Supply output for external transducers: 24VDC
- OLED graphic display, horizontally or vertically configurable
- Configuration of the meter via mini USB interface via the free eCon software
- SKU:
- ML2-2ff
- Variations in:
-
- Supply Voltage
- SKU:
- N32Uff
- Variations in:
-
- Supply Voltage/Additional Outputs
- Multi-purpose input for measuring: temperature, resistance, standard signals
- Two-line LCD display with high contrast and built-in backlighting
- Possibility of displaying the measured value and time simultaneously or an uncalculated quantity or unit (programmable unit of measured quantity)
- Meter programming from keyboard or through the RS-485 interface by means of the free eCon software
- 4 alarm outputs with signalling on LED diodes, working in 7 different modes (option)
- Conversion of any measured value into an analog signal 0/4...20 mA or 0...10 V (option)
- Storage of minimal and maximal values for all measured quantities
- Supply of object transducers
- 32-point individual characteristic for the measured value
- Mathematical functions for converting the measured value
- Mounting dimensions: 96 x 48 x 93mm
- SKU:
- N32Hff
- Variations in:
-
- Supply Voltage/Additional Outputs
- Voltage measurement ±600V (maximum range display ±1200V), current measurement via shunt, power, energy and capacity measurement of DC circuits
- two-line LCD display with high contrast and built-in backlighting
- possibility of displaying the measured value and time simultaneously or an second measured value or unit (automatically displayed unit of measured quantity)
- Wide range of voltage measurement at the shunt input up to 1500 mV
- high sampling frequency of measured signals
- programming parameters via buttons or RS-485 interface and free e-con software
- 4 alarm outputs with signaling on LEDs, working in 7 different modes (option)
- pulse output to control energy consumption
- conversion of any measured value into an analog signal 0/4-20 mA or 0-10V (option)
- memory of minimal and maximal values for all measured quantities
- automatic voltage measurement compensation function
- Mounting dimensions: 96 x 48 x 93mm
- SKU:
- ND20LITE
- SKU:
- ND30IoTff
- Variations in:
-
- Supply Voltage
- Measurement of 54 parameters and harmonics up to the 63rd harmonic for current and voltage in symmetrically or asymmetrically loaded single-phase 2-wire systems and three-phase 3-or 4-wire systems.
- 3.5" colour TFT graphic display, 320 x 240 pixels, user-programmable arangement of parameters in the displays (8 parameters in each of the 10 display pages)
- Displays that take into account the values of the programmed turn ratios
- Memory for maximum and minimum values
- 2 configurable alarm outputs
- Function of the monitoring relays for alarm outputs, optional: analogue output 0/4-20mA and 2 Pt100 inputs
- Optional RS-485 interface - Modbus protocol
- Archiving of up to 32 measurement parameters in internal 8GB data memory (optional)
- Modern and user-friendly Ethernet 10/100 BASE-T'm interface (otpional):
- Protocol: MODBUS TCP/IP, HTTP, FTP, Services: Web servber, FTP server, DHCP
- MQTT protocol for IoT applications
- Parameter programming via free eCon software
- Real time clock (RTC) with battery backup
- SKU:
- N32Pff
- Variations in:
-
- Supply Voltage/Additional Outputs
- Measurement of single-phase network parameters: voltage, current, active, reactive and apparent power, cos phi, tan phi, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
- Current and voltage harmonics analysis up to 51st (measurements available via RS-485).
- Two-line LCD display with high contrast and built-in backlighting
- Possibility of displaying the measured value and time simultaneously or an second measured value or unit (automatically displayed unit of measured quantity)
- Programmable measuring range (current 1 A / 5 A and voltage 100 V /230 V / 400 V)
- High sampling frequency of measured signals
- Programming parameters via buttons or RS-485 interface and free e-con software
- 4 alarm outputs with signaling on LEDs, working in 7 different modes (option)
- Possibility to program each of the alarms to react to a different measurements
- Pulse output to control energy consumption
- Conversion of any measured value into an analog signal 0/4-20 mA or 0-10V (option)
- Memory of minimal and maximal values for all measured quantities
- Mounting dimensions: 96 x 48 x 93mm
- SKU:
- ND04ff
- Variations in:
-
- Supply Voltage
- SKU:
- GTH2448ff
- Variations in:
-
- Model:
- SKU:
- GIA0420N
- SKU:
- N20ZPLUSff
- Variations in:
-
- Input Type / Supply Voltage
- Measurement of voltage, a.c. current or frequency
- Three-colour LED display (5 digits, 14 mm high)
- Digital output RS-485 - Modbus RTU protocol.
- Two alarm outputs of OC type.
- Programmable parameters through RS-485 interface using the free eCon software
- SKU:
- N30Hff
- Variations in:
-
- Supply Voltage / Output Option
- Measurement: current and DC voltage up to 5A and 600V
- Three-colour display (14mm high), programmed in three intervals of the measured value
- Meter programming from the keyboard or through the RS-485 interface by means of the free delivered eCon software
- Four alarm outputs with signalling by LED diodes, operating in 6 different modes
- Conversion of any measured value into a 0/4...20mA, or 0...10V analog signal
- Storage of minimal and maximal values for all measured quantities
- 21-point individual characteristic for the measured value
- SKU:
- TFT1-11ff
- Variations in:
-
- Power supply
- SKU:
- GIA0420N-ex
- SKU:
- TFT1-13ff
- Variations in:
-
- Auxiliary voltage
- SKU:
- TA9648ff
- Variations in:
-
- Supply Voltage