TGU-4550, Tinytag Ultra 2, IP51, 2-Channel Data Logger for External Thermocouple
The Tinytag Ultra 2 Thermocouple data logger has got an internal temperature sensor and also uses an external thermocouple sensor for the cost-effective monitoring of temperature in a wide variety of applications.
Thermocouples are temperature sensors that are popular because of their versatility and low cost.
They typically have a fast response time, can be very small in size and are often cheap enough to be treated as disposable.
Thermocouples are available for specific applications, as diverse as aluminium smelting, air temperature monitoring and food preparation.
The Tinytag Ultra 2 Thermocouple logger supports four different types of thermocouple sensors and is compatible with both standard and miniature thermocouple plugs.
Features:
- Supports type K, J, T & N thermocouples
- Connects to standard and miniature thermocouple plugs
- Burn out response
- Automatic cold-junction compensation
- Supplied with a type K thermocouple
- 28,000 reading capacity
- High accuracy and reading resolution
- Fast data offload
- Splashproof case
- Low battery monitor
- User-replaceable battery
- USB or serial download cables
- User-programmable alarms
+ Supports four types of thermocouple - the logger supports Type K, J, T and N thermocouples. Different thermocouple types work over different temperature ranges and are used in different applications.
+ Built-in temperature channel - the data logger has a built-in temperature channel that allows ambient temperature to be monitored at the same time as the thermocouple temperature. This channel can be turned off to increase the reading capacity of the external measurements if required.
+ Two connection types - the logger supports both standard and miniature thermocouple plugs.
+ Burnout response - the logger can be set to drive readings low or high in the event of a fault with the thermocouple, highlighting that there is a problem.
+ Cold junction compensation - the logger uses automatic cold junction compensation, ensuring the accuracy of the logger in ambient conditions between -10 and +70°C.
+ Type K thermocouple included - a Type K thermocouple, that can measure from -100 to +250°C, is included with this logger.
+ Tinytag Explorer - this logger works with the popular Tinytag Explorer software, that allows users to easily combine data from different Tinytag data loggers and to export data to other programs. The software is also used to set the type of thermocouple being used.
Technical Data:
Thermocouple types & measuring ranges:
-
Type K (-270 to +1370°C / -454 to 2498°F)
-
Type J (-210 to +1200°C / -346 to 2192°F)
-
Type T (-270 to +400°C / -454 to 752°F)
-
Type N (-270 to +1300°C / -454 to 2372°F)
Reading resolution: 0.01°C
Accuracy: Better than ±1.0°C across all thermocouple ranges when the logger is between -10 & +70°C.
Reading capacity: 28,000 readings (approximately)
Memory type: Non Volatile
Trigger start: Magnetic Switch
Delayed Start: Relative / Absolute (up to 3650 days)
Stop options:
When full Never (overwrite oldest data)
Reading types: Actual, Min, Max
Logging interval: 1 sec to 10 days
Alarms: 4 fully programmable; latchable
Cold junction compensation: -10 to 70°C
Housing IP rating: IP51
Working temperature range: -40 to +85°C (-40 to +185°F)
Battery life: more than one year
Housing dimensions: Height: 42mm / 2.83”
Width: 60mm / 2.36”
Depth: 33mm / 1.30”
Weight: 65g / 2.29oz
Internal temperature measurement:
Measuring range: -40 to +85°C (-40 to +185°F)
Internal sensor type: 10K NTC Thermistor
Response time: 20 mins to 90% FSD in moving air
Reading resolution: 0.02°C or better
Accuracy: Better than ±0.5°C
Supplied Type K Thermocouple:
Temperature range: -100 to +250°C (-148 to 482°F)
Lead length: 1m / 39.37"
The thermocouple data logger comes with a simple type K thermocouple without any other accessories.
Please contact us if you need a specific thermocouple.
Optional accessories (please order extra):
SWPK-7 USB-INT Starter pack: TINYTAG EXPLORER Software and
USB port cable with quick start guide in English, French, Italian,
Spanish and Swedish.
ACS-6000 Trigger start magnet (only necessary, if you intend to use this
kind of starting the logger runs)