MU500-Ex-ia-51-..., Intrinsically Safe Temperature Transmitter for PT100 Probes, Electrically Isolated

Item number: MU500-Ex-51-ff

  • Electrically isolated: between input / output / supply voltage
  • 2 power-supply-designs with wide range of allowed supply voltage
  • 22.5 mm standard case for rail mounting TS35
  • 13 measuring ranges, selectable via rotary switch at front panel
  • Offset and span adjustable
  • Input intrinsically safe ATEX II (1) G [Ex ia] IIC, II (1) D [Ex iaD]
  • Category: Measuring Transducers

    Supply Voltage:

    378,42 €

    including19% VAT.

    Exp. shipping time: ca. 1-2 weeks

    There are variations of this item. Please select the variation you wish.


    Description

    MU500-Ex-ia-51-..., Intrinsically Safe Temperature Transmitter for PT100 Probes, Electrically Isolated

    These temperature transmittersoffer an intrinsically safe input and convert RTD sensor signals (Pt100) into industry standard signals. The device includes a full 3-port isolation.

    Properties:
    • Electrically isolated: between input / output / supply voltage
    • 2 power-supply-designs with wide range of allowed supply voltage:10-30VDC / 10-42VAC or 85-265VAC / 110-125VDC
    • 22.5 mm standard case for rail mounting TS35
    • 13 measuring ranges, selectable via rotary switch at front panel
    • Offset and span adjustable
    • Input intrinsically safe ATEX II (1) G [Ex ia] IIC, II (1) D [Ex iaD]
    • Burden: max. 1000 Ohm

    Technical data:
    Measuring ranges: selectable via rotary switch
    PT100: -50 ... 0, -50 ... 50, -30 ... 20, -30 ... 70, -20 ... 30,
    -20 ... 80, 0 ... 50, 0 ... 100, 0 ... 150, 0 ... 200,
    0 ... 300, 0 ... 450, 0 ... 600 C

    Offset adjust: offset: approx. 8Ohm (^= 20 C)
    Span: approx. 20 %
    Sensor connection: 2- or 3-wire connection
    Sensor current: approx. 1 mA (Pt100)
    Output signal: 0 - 20 mA, 4 - 20 mA, 0 - 10 V or 2 - 10 V (selectable via DIP switch)
    Max. load: burden < =1 kOhm (at mA), load: max. 15 mA (at V)
    Basic accuracy: < =0.2 % of measuring range
    Temperature coeffi cient: < =0.01 %/K
    Output accuracy: < =0.1 % of measuring range
    Power supply: (... - 0): 85 ... 265 V AC / 110 ... 125 V DC
    (... - 5): 10 ... 42 V DC / 10 ... 30 V AC
    Power consumption: max. 2.2 W / 3.3 VA
    Isolation voltage: 500 V AC, according to VDE 0110 Gr. 2
    between input/output/supply voltage
    Test voltage: 4 kV DC between input/output/supply voltage
    Working temperature: -10 .. 60 C
    Electrical connection: screw-terminals with pressure plates, max. 2.5 mm
    Dimensions: 22.5 x 75 x 110 mm (W x D x H)
    Protection: IP 30 (case), IP 20 (terminals)

    Ex-certification: TV 03 ATEX 2283, II (1) G [Ex ia] IIC, II (1) D [Ex iaD]
    Connection data:
    MU 500-ex-ia-51-..: U0 = 1.3 V, I0 = <3 mA, P0 = <3 mW, C0 = 29 ?F,
    L0 = 100 mA, Ci = 5 nF, Li = 0 mH

    Please specify the power supply range which you need when ordering.
    Ordering example:
    MU 500-ex-ia-51-5: Intrinsically safe version, Input =PT100, Power supply: 10 ... 42VDC / 10 ... 30 VAC

    PT100 temperature probes are not supplied with this article and need to be ordered separately.
    Please contact us if there are any questions about the probes.

    Ratings (0)

    Average product review

    Write your first review and help others with their purchase decision: