Description
TR-1201, Ultra Radio Count Data Logger
The TR-1201 is a count logger recording 0 to 32,000 counts per interval. The logger's design makes it ideal for discreet indoor monitoring in a variety of buildings. This logger is a component part of the Tinytag Radio data logging system, which automatically sends data from multiple loggers via a receiver for viewing on a PC.
This unit is supplied with an input lead (CAB-3246).
Alternatively you can buy our 2-pin connector plug (ACS-9700) to connect to your own probe/sensor.
This logger is part of a system that requires a receiver and Tinytag Explorer software (ACSR-3030-PK) as optional accessories.
The logger can also be powered from the mains using an optional plug-in power supply (ACS-0005).
If the power supply is interrupted, the logger?s batteries will power the logger and continue recording until the supply is restored.
Please note: this product is only for sale in the EU.
Please note: This article is only one component of the Tinytag Radio Logger System.
For proper operation minimum one radio data logger and one Tinytag radio receiver with accompanying software are necessary!
Features:
- Count monitoring
- Robust data network
- Easy to install
- Alarm e-mails
- 200m typical range (line of sight)
- High accuracy and reading resolution
- 12 month battery life
- Low battery monitor
- User-replaceable battery
Popular applications:
? Light Industrial:
- Flow rate (liquids and gas)
- Conveyor belt monitoring
Art Galleries and Museums:
- People counting
Technical data:
Reading range: 0 to 32,767 counts per logging interval
Max. frequency: 250 counts/second
Logger resolution: 0.02°C or better
Input type: digital or volt-free contact switch
Digital Input:
Low level: -0.3V to +0.3V
High level: 2V to 10V
Min. pulse width: 150us
Min. pulse separation: 2ms
Edge detection: high-low transition
Contact input:
Type: normally open (with minimal de-bounce)
Min. closed time: 150us
Min. open time: 1ms
Edge detection: open to closed
Radio frequency: 869.88MHz (EU version, AUS versions upon request )
Radio power: <5mW
Radio range: 200m, typical (line of sight).
Radio licence: no licence required (SRD)
Offline memory capacity: 2 weeks typical, at a 10 minute logging interval
Memory type: non volatile
Logging interval: 2 minutes to 10 days
Alarms: 2 programmable latching alarms (upper and lower) per channel
Alarm delay: 1 second to 10 days
Low battery monitor: software warning
Battery type: Duracell Procell MN1500 LR6 AA 1.5V (supplied)
Battery life: typically 12 months
IP Rating: IP20
Operational Range: -20°C to +55°C
Case Dimensions: 121 x 79 x 24mm³ (L x W x D, excluding antenna)
Weight: 180g
Optional accessories:
ACS-0005 Power supply for Ultra Radio dataloggers
ACSR-3030-PK Pack: Ultra Radio receiver, software, 5m USB cable, power supply
ACS-9700 2-pin plug for user's own count connection