TK-4703-PK, Tinytag Talk 2, 16 Bit, IP30, Voltage Input Logger, 0-2,5VDC

Item number: TK-4703-PK

  • self-contained voltage recorder with input cable
  • measuring range: 0-2,5VDC
  • resolution: 16 bit, 50µV or better
  • 16,000 reading capacity
  • film canister housing with IP30 protection
  • user-settable alarms
  • Category: Gemini Tinytag Talk 2


    99,96 €

    including 19% VAT.

    Exp. shipping time: ca. 2 weeks

    : 7 workdays

    pc.


    Description

    TK-4703-PK, Tinytag Talk 2, 16 Bit, IP30, Voltage Input Logger, 0-2,5VDC

    Supplied with the input cable CAB-3233, this inexpensive logger can measure voltages up to 2.5V DC and can be connected to many industry standard devices, such as CO2 sensors and current clamps, enabling the logging of a wide range of process parameters.

    This unit is mainly designed for indoor applications and is IP30 rated. It is particularly useful when space is at a premium.

    Tinytag Talk 2s are compact, lightweight, economical loggers housed in a 35mm film canister.
    These loggers are used in a wide range of applications including fridge monitoring, building condition monitoring and academia. They have a memory capacity of 16,000 readings, a fast response time, a big readings memory and a low battery monitor.

    Popular Application:
    • Battery condition monitoring
    • Customised data logging:
               CO2
               Pressure
               Flow Rate
               Light
               Power (with a current clamp)

    Features:
    • Self-contained voltage recorder
    • 16,000 reading capacity
    • High Accuracy and reading resolution
    • Fast Data Offload
    • Low battery monitor
    • User-replaceable battery
    • User-programmable alarms


    Technical data:
    Measuring range: 0 to 2.5 VDC
    Maximum input voltage: 3 VDC
    Resolution: 8 Bit, 50µV
    Input impedance: 470kOhm
    Accuracy: ±0.2% of reading ±5mV
    Memory: 16,000 readings, non-volatile
    Delayed Start: Relative / Absolute (up to 45 days)
    Stop Options: When full
                          After n Readings
                          Never (overwrite oldest data)
    Logging Interval: 1 sec to 10 days
    Offload: While stopped or when logging in minutes mode
    Alarms 2 fully programmable; latchable
    Housing protection. IP30
    Operational Range: -40°C to +85°C (-40°F to +185°F)
    Housing sizes. Ų34mm x 54mm
    Weight: 30g


    Optional accessories (please order extra):
    SWPK-5 USB-INT Starter pack: TINYTAG EXPLORER Software and
    USB port cable with quick start guide in English, French, Italian, Spanish and Swedish.