PicoLog CM3, 3-Channel Mains Current Logger (without Current Clamps)
The PicoLog CM3 Current Data Logger is a compact, easy–to–use data logger for measuring the power consumption of buildings and machinery.
- 3 channel current data logger
- Suitable for single or three–phase alternating currents
- Low conversion time
- High resolution and accuracy
- No power supply required
- USB and Ethernet interfaces
- Run multiple units on a single PC
High resolution and accuracy
The 24–bit resolution of your PicoLog CM3 ensures that you can detect the smallest changes in current, while with accuracy within ±1% you know that can rely on your measurements.
Take measurements at the speed you want
With a conversion time of just 720 ms per channel your PicoLog CM3 is capable of logging fast changes in current, but we know that in order to identify problems you may also need to monitor currents over long periods, so with a PicoLog CM3 you can take measurements at a speed to suit your application — whether that’s every few seconds, minutes, hours or even every few days.
Monitor currents from your desktop to the other side of the world
With both USB and Ethernet interfaces your PicoLog CM3 can be used in a variety of situations. If you need a portable instrument that can be used at various locations and is fast to set up and use, simply connect your laptop to the PicoLog CM3 by USB. Need to monitor a situation over a period of hours or days, or from a remote location? Plug your PicoLog CM3 into a spare port on your network and then access it remotely either from your LAN or over the internet — thanks to Power over Ethernet (PoE) technology you don’t even need a separate power supply.
Software that does what you need it to
Your PicoLog CM3 Current Data Logger is supplied with PicoLog data logging software. With PicoLog you can collect up to one million measurements, analyse them and then display the results in both spreadsheet and graphical formats. You can view the data both in real–time as you are collecting the measurements, or you can save the data and view it later. You can also set alarms to warn you if the current goes above or below a set value.
A software development kit (SDK) is also supplied. The SDK contains a range of software drivers and example code that you can use to write your own software or to use your PicoLog CM3 with third–party software such as LabVIEW.
Both PicoLog and the SDK are provided free of charge and updates can be downloaded for free.
Create your own data acquisition system
With a PicoLog CM3 you can measure three separate currents. If that’s not enough, using PicoLog software you can add a further 19 PicoLog CM3s to your PC — enabling you to simultaneously measure up to 60 currents. Alternatively, you can mix–and–match Pico data loggers to create your own custom data acquisition system. For example, you may want to monitor how the opening and closing of doors affects the temperate and electricity usage of a cold room. You could do this with a PicoLog CM3 and a PT-104.
The only current data logger you need
With three channels, high accuracy and low noise, a PicoLog CM3 Current Data Logger is ideal for recording data from both single–phase and three–phase AC supplies. While its compact size, together with both USB and Ethernet interfaces gives you a versatile instrument that you can take with you or leave on–site for remote monitoring.
Whether you need to monitor three–phase motors and generators, measure the current consumption of
HVAC systems or simply monitor the current consumed around the home or office, a PicoLog CM3 Current Data Logger is the only current data logger you need.
Technical data current logger:
PicoLog CM3 Current Data Logger Specifications |
Number of chanels
|
3 |
Range (voltage input)
|
0 to 1 V AC RMS
|
Accuracy (voltage input)
< 200 mV RMS
< 1 V RMS
|
±1%
±2.5% |
RMS Noise
|
60 µV |
Resolution
|
24 bit |
Conversion time per enabled channel
|
720 ms |
Voltage input
|
1 V RMS, 20 Hz to 1 kHz |
Input connectors
|
4 mm sockets |
Input impedance
|
>1 MOhm, AC coupled |
Overload protection
|
±30 V DC |
PC Requirements |
Minimum |
Processor: Pentium II processor, or equivalent
Memory: 64 MiB (XP) / 512 MiB (Vista) / 1 GiB (Win 7)
Operating system: 32– or 64–bit edition of Microsoft Windows XP SP2, Vista or Windows 7
Ports: USB 1.1 compliant port or Ethernet |
Recommended |
Processor: 2 GHz Pentium IV processor, or equivalent
Memory: 256 MiB (XP) / 1 GiB (Vista / Win 7)
Operating system: 32– or 64–bit edition of Microsoft Windows XP SP2 (or above), Vista or Windows 7
Ports: USB 2.0 compliant port or Ethernet |
Environmental |
Operating environment
Temperatue range
Humidity range |
0 °C to 50 °C (20 °C to 28 °C for stated accuracy)
20% to 80% RH, non–condensing |
Storage environment
Temperatue range
Humidity range |
-20 °C to +60 °C
5% to 95% RH, non–condensing |
Physical Properties |
Dimensions |
184 x 135 x 36 mm (approx 7.2 x 5.3 x 1.4 in) |
Software |
PicoLog for Windows |
PicoLog data acquisition software can collect up to 1 million samples. Features include:
Multiple views - view data as a graph, spreadsheet or text
Parameter scaling - convert raw data into standard engineering units
Math functions - use mathematical equations to calculate additional parameters
Alarm limits - program an alert if a parameter goes out of a specified range
IP networking - transfer measurements via a LAN or over the Internet |
Software development kit |
A growing collection of drivers and example code for various programming languages. |
Language Support |
Software
PicoLog |
Full support for English, French and German; menus only for Italian, Spanish and Swedish |
Documentation
User’s guide
Programmer’s guide
Installation guide |
English, Français, Deutsch, Italiano, Español, ??
English
English, Français, Deutsch, Italiano, Español, Svenska, Nederlandse, Dansk |
General |
Data sheet |
English, ?? (??), Deutsch, Español, Français, Italiano |
Additional hardware (supplied) |
USB 2.0 cable, Ethernet cable, user manuals, software CD–ROM |
PC interface |
USB 2.0 (USB 1.1 compatible) or Ethernet |
Power requirements |
Powered from USB port or Ethernet |
Compliance |
European EMC and LVD standards
FCC Rules Part 15 Class A
RoHS compliant |
Warranty |
5 years |
Download data sheet PicoLog CM3 (click here!)
Please note: This logger is supplied without current clamps, which need to be ordered separately.
See below for suitable clamps and see also the PicoScope CM3 Set.